Home
Fire Sprinklers
Standart Spray
F1FR56, 3mm bulb K=5.6[80],1/2", St. Coverage, Quick Response , Pendent Sprinkler
The Series F1FR56 5.6 factor,Pendent Sprinklers described in this data sheet are quick response- standard coverage,decorative 3 mm glass bulb type spray sprinklers designed for use in light, ordinary hazard
(014%20Model%20F1FR%2056%20Quick%20Response%20Sprinklers.pdf, 413 Kb) [Download]
(?)
Approvals
Approvals:FM
Approvals:UL
Approvals:ULC
(?)
Manufacturing Companies
(?)
175(12Bar)
Max Working Pressure
Sprinklers (?)
(?)
Sprinkler Pipe Connection
1/2" NPT
Quick
(?)
Sprinkler Hazard Classification
Light Hazard
OH
Extra Hazard
Standard
5.6(80)
pendent
57°C(135°F)
68°C(155°F)
79°C(175°F)
93°C(200°F)
141°C(286°F)
White
Categories
- Standard Upright Sprinklers
- Standard Pendent Sprinklers
- Standard Sidewall Sprinklers
- Other Type Sprinkler
- Storage Sprinklers
- EC Sprinklers
- Special Sprinklers
- Dry Sprinklers
- Residental Sprinklers
- Sprinkler Accesories
- Spray Nozzles
- Wet Pipe Alarm
- Dry Pipe Valves
- Deluge Valves
- Preaction Valves
- OSY Gate
- Butterfly Valves
- NRS Gate Valves
- Pressure Relief
- Pressure Reducing
- Swing Check
- Ball Valves
- Angle Valves
- Globe
- Backflow Valves
- Air Release
- FDC
- Switches/Sensors
- Grooved Couplings
- Grooved Fittings
- Flexible Hoses
- Flanges
- Strainer
- Cpvc Fittings
- Seamless Pipe Fittings
- UDG HDPE Fittings
- UDG Ductile Fittings
- Fiber Reinforced Composite Fittings
- Polyvinyl Chloride (PVC) Fittings
- Pipe Outlets
- Hanger Components
- Fire Hose
- Signs
- Panels & Plates
- Hose Fog Nozzles
- Portable Extinguishers
- Grooving Machine
- Hand Tools Seismic
- Cutting Tools
- Hole Cutting Tools
- Test Pump
- Pipe Threading Machine
- Miscellaneous
- Flow Meters
- Indicator Posts
- Pressure Gauges
- Roadway Box
- Flange Bolting Kit PN16
- Single Interlock System Wet Pilot Actuation
- Single Interlock System Dry Pilot Actuation
- Single Interlock System Electric Actuation
- Double Interlock System Electric/Pneumatic Actuation
- Double Interlock System Electric/Electric Actuation
- Single Interlock Electric Actuation
- Single Interlock Wet Pilot Line
- Single Interlock Dry Pilot Line
- Double Interlock Type F Electric / Pneumatic Actuation
- Double Interlock Type D System Electric / Pneumatic Actuation
- Deluge Valve Trim For DV-5
- Flange Bolting Kit Ansi125
- NRS Valve Trim
- Air Pressure Maintenance Devices, Special Sprinkler Systems
- Accelerators with Built-in Antiflooding Device
- Accelerators and Exhausters
- Deluge Valve Trim DDX-LP
- Deluge Valve Trim Model H
- Preaction Valve Trim Model H Reliable
- Pump Trim Kit
- Pipes
- Nipples
- Indoor Fire Hose Cabinets EN 671-1
- Indoor Fire Hose Cabinets EN 671-2
- Outdoor Fire Hose Cabinet Stations
- Foam Based Fire Hose Reels
- Hose Rack
- Hose Valves
- Fire Hydrants
- HSC Fire Pumps
- End Suction
- Vertical Turbine
- In Line Fire Pumps
- Jockey Pumps
- Diesel Controller Options C
- Diesel Controller Options D
- Diesel Controller Options E
- Diesel Controller Options F
- Electric Controller
- Automatic Transfer Switch
- Jockey Pump Controller
- Discharge Devices
- Proportioners
- Foam Concentrate
- Foam Tanks
- Custom Fabricated Skid Packages
- Hi- Ex Foam Extinguishing Systems
- Low Expansion Foam Systems
- CAF Systems
- Foam Concentrate Pumps
- Special Hazard Syst.
- 1. RWA Control Centres
- 4. Ventilation Control Systems
- 5. Accesories for RWA Controls centres and ventilation control systems
- Pneumatic Control Mechanism and Controls
- Fire & Smoke Curtains
- Powered Smoke Vents
- General Ventilation
- Natural Air Inlets
- Fire and Smoke Dampers
- Wooden Door Fire Stops
- Steel Door Fire Stops
- Glazing Fire Stops
- Facade/Panel Fire Stops
- Fire Damper Fire Stops
- Profiles
- Cable Penetration
- Fire Stops For Joint with movement up to 360 mm width
- Fire Stops For Joints without movement up to 300 mm width
- Structural Steel
- Combustible Pipes Fire Stops
- Fire Stops For Other Combustible Pipes
- Fire Stop For PP Pipes
- Fire Stop For Steel pipe without insulation
- Fire Stop for steel pipe with m. wool insulation
- Steel pipe with combustible insulation:
- Fire Stop for copper pipe with combustible insulation
- Alu-Spiro-pipe
- Air ducts (joint)
- Multi-Penetrat.
- Smoke Detectors
- Heat Detectors
- Flame Detectors
- Beam Detectors
- Linear Heat Detection
- Thermal Image Detection
- Fire Alarm Control Panels
- Sound and Light Alarm Devices
- Cross Zone Extinguishing Panel
- Rental Tools
- Fire Doors
Please enter your name to proceed: